Comparative evaluation of radiological anatomy knowledge and accuracy of ChatGPT-5, Gemini 2.5, and Grok 4 across normal and thinking modes


Sivri İ., Özden F. M., Celik H., Gokturk O., Çolak T.

ANATOMICAL SCIENCES EDUCATION, cilt.19, sa.9, ss.1377-1385, 2026 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 19 Sayı: 9
  • Basım Tarihi: 2026
  • Doi Numarası: 10.1002/ase.70292
  • Dergi Adı: ANATOMICAL SCIENCES EDUCATION
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Agricultural & Environmental Science Database, EBSCO Education Source, Education Abstracts, EMBASE, ERIC (Education Resources Information Center), MEDLINE, Psycinfo, Social Science Premium Collection (ProQuest), Biomedical Reference Collection: Corporate Edition (EBSCO), Education Collection (ProQuest), Education Source Ultimate (EBSCO), Health Research Premium Collection (ProQuest)
  • Sayfa Sayıları: ss.1377-1385
  • Anahtar Kelimeler: artificial intelligence, diagnostic imaging, large language models, medical education, radiologic anatomy
  • Kocaeli Üniversitesi Adresli: Evet

Özet

This study compared the performance of three large language models, ChatGPT-5 Plus, Gemini 2.5 Pro, and SuperGrok 4, in identifying anatomical structures on radiographic images using standardized anatomical terminology. Thirty radiographs from different body regions were selected from an open-access atlas and analyzed by the models in Normal and Thinking modes using standardized prompts based on Terminologia Anatomica (version 2.07). Responses were evaluated independently by two anatomists using a 0-2 scoring system. Overall accuracy across both modes and models ranged from 47.4% to 85.7%. Data were analyzed using Friedman and Wilcoxon signed-rank tests. Temporal response consistency was assessed with weighted kappa coefficients. Gemini 2.5 Pro and ChatGPT-5 Plus significantly outperformed SuperGrok 4 in both modes. In Normal mode, Gemini 2.5 Pro achieved the highest overall accuracy (82.7%), significantly exceeding ChatGPT-5 Plus (60.7%, p = 0.001) and SuperGrok 4 (47.4%, p < 0.001). In Thinking mode, accuracies were 85.7% for Gemini 2.5 Pro, 77.6% for ChatGPT-5 Plus, and 49.5% for SuperGrok 4. Gemini 2.5 Pro demonstrated a significant advantage over ChatGPT-5 Plus only in Normal mode (p = 0.001), whereas Thinking mode significantly improved performance only for ChatGPT-5 Plus (p = 0.01). Temporal stability analysis showed high response consistency for Gemini 2.5 Pro and SuperGrok 4 across all modes (r > 0.94, p < 0.001). Conversely, ChatGPT-5 Plus' stability decreased from substantial agreement in normal mode (r = 0.697, p < 0.001) to moderate agreement in Thinking mode (r = 0.539, p < 0.001). Despite their educational potential, these models need refinement to reliably identify anatomical structures on radiographic images.