PCDD/F removal efficiencies of electrostatic precipitator and wet scrubbers in izaydas hazardous waste incinerator
FRESENIUS ENVIRONMENTAL BULLETIN, cilt.12, sa.10, ss.1228-1232, 2003 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 12 Sayı: 10
- Basım Tarihi: 2003
- Dergi Adı: FRESENIUS ENVIRONMENTAL BULLETIN
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Sayfa Sayıları: ss.1228-1232
- Kocaeli Üniversitesi Adresli: Evet
Özet
PCDD/F removal efficiencies of the electrostatic precipitator and the wet scrubbers in IZAYDAS Incinerator were examined in a trial burn. Both units showed removal efficiencies higher than 90% for all congeners and homologues, producing >99% removal of PCDD/Fs. Congener and homologue profiles did not change significantly through ESP, but highly-chlorinated PCDD/Fs dominated after the wet scrubbers, suggesting that lower-chlorinated PCDD/Fs with high volatility are removed in higher rates.