PCDD/F removal efficiencies of electrostatic precipitator and wet scrubbers in izaydas hazardous waste incinerator


Karademir A., Bakoglu M., Ayberk S.

FRESENIUS ENVIRONMENTAL BULLETIN, vol.12, no.10, pp.1228-1232, 2003 (SCI-Expanded) identifier identifier

  • Publication Type: Article / Article
  • Volume: 12 Issue: 10
  • Publication Date: 2003
  • Journal Name: FRESENIUS ENVIRONMENTAL BULLETIN
  • Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Page Numbers: pp.1228-1232
  • Kocaeli University Affiliated: Yes

Abstract

PCDD/F removal efficiencies of the electrostatic precipitator and the wet scrubbers in IZAYDAS Incinerator were examined in a trial burn. Both units showed removal efficiencies higher than 90% for all congeners and homologues, producing >99% removal of PCDD/Fs. Congener and homologue profiles did not change significantly through ESP, but highly-chlorinated PCDD/Fs dominated after the wet scrubbers, suggesting that lower-chlorinated PCDD/Fs with high volatility are removed in higher rates.