Comparison of the efficacies of two different fiber post-removal systems: A micro-computed tomography study


Arukaslan G., Aydemir S.

MICROSCOPY RESEARCH AND TECHNIQUE, vol.82, no.4, pp.394-401, 2019 (SCI-Expanded, Scopus) identifier identifier identifier

  • Publication Type: Article / Article
  • Volume: 82 Issue: 4
  • Publication Date: 2019
  • Doi Number: 10.1002/jemt.23180
  • Journal Name: MICROSCOPY RESEARCH AND TECHNIQUE
  • Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Page Numbers: pp.394-401
  • Kocaeli University Affiliated: Yes

Abstract

The aim of this in vitro study was to compare the efficacies of two different fiber post-removal systems. Thirty extracted single-rooted mandibular premolar teeth were used. After RelyX fiber posts were cemented, the teeth were divided into two groups with regard to the post removal techniques: ultrasonic vibration and D.T. Light-Post removal kit. Residual material, tooth volume changes, working time and micro-crack formation were assessed using micro-computed tomography. All data were analyzed using Wilcoxon signed-rank and Mann-Whitney U tests. There was significantly more tooth root volume change in the ultrasonic group than removal kit group (p < .05). Fiber post removal time for the ultrasonic group was significantly longer than the removal kit group (p < .01).