Özet
Power transformers are among the most critical assets in electrical power systems, making reliable condition assessment essential for maintaining operational reliability and supporting effective maintenance strategies. DGA is widely employed for transformer condition assessment, and the DGAF constitutes an important component of DGA-based evaluation frameworks. However, conventional DGAF calculations employ fixed gas-weighting coefficients and therefore do not explicitly account for temporal variations in gas-generation behavior. This study proposes a rate-modulated adaptive weighting methodology that dynamically updates conventional gas weighting coefficients according to gas generation rates calculated in accordance with IEEE C57.104-2019. The proposed approach employs a thresholded-sigmoid amplification function based on gas generation rates normalized with respect to the corresponding IEEE 95th-percentile critical rate values, while preserving the conventional DGAF formulation and its underlying weighting structure. The methodology was evaluated using approximately ten years of DGA measurements obtained from an in-service power transformer. The results demonstrate that the proposed adaptive weighting mechanism increases the contribution of diagnostically significant gases during periods of accelerated gas generation, while maintaining weighting coefficients close to their conventional values when generation rates remain below the corresponding critical levels. Accordingly, the proposed methodology provides a rate-sensitive and physically interpretable approach for DGAF calculation that incorporates temporal gas generation behavior without modifying the conventional DGA scoring framework. The findings demonstrate the applicability of the proposed approach as a decision-support methodology for dynamic DGA assessment, while further evaluation using datasets from multiple transformers and independent condition evidence is required to establish its broader diagnostic and prognostic validity.