ENVIRONMENTAL FORENSICS, cilt.19, ss.79-86, 2018 (SCI-Expanded)
This study addresses the odor problem at a waste and residue treatment incineration and utilization plant located within the borders the Alikahya district of the Kocaeli province in Turkey. In the first stage of the study, odor measurements were made at designated sampling points, while in the second stage, odor concentrations were determined at the receptor points through dispersion modelling using a USEPA (United States Environmental Protection Agency) certified long-range (>50 km) CALPUFF lagrangian puff model. In the final stage, an analysis of the predicted and observed values was carried out using such statistical methods as geometric mean bias (MG), geometric variance (VG) and fractions of predictions within a factor of two observations (FAC2).