Comparison of Performance Characteristics of DxN VERIS System versus Qiagen PCR for HBV Genotype D and HCV Genotype 1b Quantification


SAYAN M. , Arikan A., Sanlidag T.

POLISH JOURNAL OF MICROBIOLOGY, cilt.68, ss.139-143, 2019 (SCI İndekslerine Giren Dergi) identifier identifier identifier

  • Cilt numarası: 68 Konu: 1
  • Basım Tarihi: 2019
  • Doi Numarası: 10.21307/pjm-2019-008
  • Dergi Adı: POLISH JOURNAL OF MICROBIOLOGY
  • Sayfa Sayıları: ss.139-143

Özet

The Beckman Coulter DxN VERIS system is a fully automated, closed molecular diagnostic instrument for viral load quantification of hepatitis B virus and hepatitis C virus. In this study, the analytical performance of this new system was compared to routine diagnostic Qiagen PCR kit by using the same clinical samples. The DxN VERIS system demonstrated a high analytical performance. The DxN VERIS allows random access, which means that samples can be uploaded straight on to the system at any time; so, it provides an improvement of workflow, staff productivity and allows faster turn-around of viral load results.