Investigation of a multi-dropped liquid membrane system for the transport of uranium ions with tri-n-octyl phosphine oxide


ESEN ERDEN K., Donat R., Aytas Ş.

Journal of the Iranian Chemical Society, cilt.20, sa.6, ss.1247-1256, 2023 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 20 Sayı: 6
  • Basım Tarihi: 2023
  • Doi Numarası: 10.1007/s13738-023-02752-7
  • Dergi Adı: Journal of the Iranian Chemical Society
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier
  • Sayfa Sayıları: ss.1247-1256
  • Anahtar Kelimeler: MDLM, Uranium, Transport, TOPO, Extraction
  • Kocaeli Üniversitesi Adresli: Evet

Özet

The kinetics of U(VI) ion transport from an aqueous donor phase to an aqueous acceptor phase were investigated using a recently designed system, the multi-dropped liquid membrane system (MDLM). Equilibrium and kinetic studies were performed involving the extraction of U(VI) from an aqueous nitrate medium into tri-n-octyl phosphine oxide (TOPO). The influences of temperature, carrier, and donor phase concentrations were investigated. U (VI) was extracted from the donor phase to the acceptor in 45 min with an extraction efficiency of about 99.62% under optimum conditions. The interface reactions' kinetic parameters (k1, k2, CBmax, tBmax, Jdmax, Jamax) were estimated on the assumption of two successive, irreversible first-order reactions. This study investigated the conditions of transport by TOPO in the extraction of U(VI) ions in the MDLM system and obtained successful results.