Biomechanical Comparison of Conventional Technique Versus Oblique Screw Placement in Plate Fixation


Karadeniz E., Balcik B. C., Demirors H., Tuncay I. C.

JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, cilt.70, sa.5, 2011 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 70 Sayı: 5
  • Basım Tarihi: 2011
  • Doi Numarası: 10.1097/ta.0b013e318214094d
  • Dergi Adı: JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Anahtar Kelimeler: Biomechanics, Fractures, Internal fixation, Plate osteosynthesis, STRENGTH
  • Kocaeli Üniversitesi Adresli: Evet

Özet

Background: The aim of this study was to evaluate whether plate fixation with screws in an oblique fashion would change the strength of the fixation to bending forces and whether any relationship existed between deformity and increased strength of fixation.